Part Number Hot Search : 
DRH6D SBTJ7S 330M2 10003 TK61023 DP308 D8066D 00BGXI
Product Description
Full Text Search
 

To Download ADAM-4914V Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  www.advantech.com/products online download 2-ch counter/frequency modules (with 7-segment led display) 4-ch voltage input surge protection module adam-4080/4080d ADAM-4914V specifcations general connectors 2 x plug-in terminal block (#14 ~ 22 awg) power consumption 2.0 w @ 24 v dc power input unregulated 10 ~ 30 v dc humidity 5 ~ 95% rh operating temperature -10 ~ 70 c (14 ~ 158 f ) storage temperature -25 ~ 85 c (-13 ~ 185 f ) watchdog timer system (1.6 second) support protocol ascii command led indicators 5-digit readout, ch 0 or ch 1 (programmable) (adam-4080d only) counter input channels 2 independent 32-bit counters input frequency 50 khz max. (non-isolation) input pulse width >10 s. input mode lsolated or non-isolated isolated input level logic level 0: +1 v max. logic level 1: 3.5~30 v isolation voltage 2500 v rms non-isolated programmable threshold: input level logic level 0: +0.8 v max. logic level 1: 2.4 ~ 5.0 v maximum count 4,294,967,295 (32 bits) preset type absolute or relative (adam-4080 only) programmable digital 2 s ~ 65 ms noise filter alarm adam-4080: alarm comparators on each counter adam-4080d: high and low comparators on counter 0 frequency measurement range 5 hz ~ 50 khz programmable built-in 1 or 0.1 second gate time digital output channels 2 open collector 30 v, 30 ma max. load power dissipation 300 mw for each channel ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? adam-4080/4080d ordering information adam-4080/4080d 2-ch counter/frequency modules (with 7-segment led display) ADAM-4914V 4-ch voltage input surge protection module ? ? ADAM-4914V specifcations general connectors 2 x plug-in terminal block (#14 ~ 22 awg) humidity 5 ~ 95% rh operating temperature -10 ~ 70 c ( 14 ~ 158 f ) storage temperature -25 ~ 85 c (-13 ~ 185 f ) input channels 4 differential voltage and thermocouple input performance discharge current 5000 a (8/20 sec.) discharge voltage between lines: 18 v min. line to gnd: 350 v max. internal series approx. 20 ? including resistance return max. surge voltage between lines: 23 v min. line to gnd: +4,000 v max. leakage current between lines: 10 a @ 7.5 v dc line to gnd: 5 a @ +140 v dc maximum line voltage 10 v response time 0.1 sec. ? ? ? ? ? ? ? ? ? ? ? ?


▲Up To Search▲   

 
Price & Availability of ADAM-4914V

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X